5: Troubleshooting
The Ops panel switch settings for a JBOD enclosure are listed in Table 5-2. The ops panel
switch settings for a RAID enclosure are listed in Table 5-3 on page 82. The switches are
read only during the power-on cycle.
System/ESI fault This LED illuminates amber and the
audible alarm sounds when the ESI
processor detects an internal problem.
This LED flashes when an over- or
under-temperature condition exists.
Contact your service
provider.
PSU/cooling/
temperature fault
This LED illuminates amber if an over-
or under-temperature condition exists.
This LED flashes if there is an ESI
communications failure.
Check for proper airflow
clearances and remove any
obstructions. If the problem
persists, lower the ambient
temperature. In case of ESI
communications failure,
contact your service provider.
Hub mode This LED illuminates green when the
host side switch is enabled (RAID
only).
N/A
2-Gb link speed This LED illuminates green when 2-Gb
link speed is detected.
N/A
Table 5-2 Ops Panel Configuration Switch Settings for JBOD
Switch
Number Function Function When Off Function When On
1 (On
a
) Loop select single
(1x16) or dual
(2x8)
LRC operates as 2 loops of 8
drives (2x8). Refer to drive
addressing mode 2.
LRC operates as 1 loop of 16 drives
(1x16 loop mode)
2 (On) Loop terminate
mode
If no signal is present on
external FC port, the loop is left
open
If no signal is present on external FC port, then the loop
is closed
3 (Off)
b
N/A N/A N/A
4 (Off)N/A N/A N/A
Table 5-1 ESI/Ops Panel LEDs (continued)
LED Description Corrective Action