Using Storage System LEDs for Troubleshooting
007-4522-003 83
Note the following:
If all LEDs on the ESI/ops panel flash simultaneously, see “Using Test Mode” on
page 93.
If test mode has been enabled (see “Using Test Mode” on page 93), the amber and
green drive bay LEDs flash for any non-muted fault condition.
9 and 10 Drive addressing mode Sw 9 Sw 10 Function
On On Mode 0 - Single loop, base 16, offset of 4,
7 address ranges
b
Off On Mode 1 - Single loop, base 20, 6 address ranges
On Off Mode 2 - JBOD, dual loop, base 8,
15 address ranges
c
Off Off Mode 3 (Not used)
11 (On) Soft select Selects switch values
stored in EEPROM
Selects switch values from hardware switches
Note: Soft select switch must be set to On
12 (Off) Not used Not used Not used
a. Bolded entries indicate SGI’s default switch settings for RAID
b. Mode 0 (switches 9 and 10 set to On) is the SGI default factory setting
c. Mode 2 (2x8) is not supported in a RAID configuration
Table 5-3 Ops Panel Configuration Switch Settings for RAID (continued)
Switch
Number Function Function when Off Function when On