Using Storage System LEDs for Troubleshooting
007-4522-003 83
Note the following:
• If all LEDs on the ESI/ops panel flash simultaneously, see “Using Test Mode” on
page 93.
• If test mode has been enabled (see “Using Test Mode” on page 93), the amber and
green drive bay LEDs flash for any non-muted fault condition.
9 and 10 Drive addressing mode Sw 9 Sw 10 Function
On On Mode 0 - Single loop, base 16, offset of 4,
7 address ranges
b
Off On Mode 1 - Single loop, base 20, 6 address ranges
On Off Mode 2 - JBOD, dual loop, base 8,
15 address ranges
c
Off Off Mode 3 (Not used)
11 (On) Soft select Selects switch values
stored in EEPROM
Selects switch values from hardware switches
Note: Soft select switch must be set to On
12 (Off) Not used Not used Not used
a. Bolded entries indicate SGI’s default switch settings for RAID
b. Mode 0 (switches 9 and 10 set to On) is the SGI default factory setting
c. Mode 2 (2x8) is not supported in a RAID configuration
Table 5-3 Ops Panel Configuration Switch Settings for RAID (continued)
Switch
Number Function Function when Off Function when On